 Switch Mode Power Supply
Power supplies
S8TS
Block-type Switch mode Power Supply That Mounts to DIN-rail
* Power supply range of 60 to 240 W available with just one model (24-V models). * Easy creation of multi-power supply configurations with different output power supplies connected together (24-V, 12-V, and 5-V models). * Improve power supply system reliability by creating N+1 redundant systems (24-V and 12-V models). * Approved by UL/CSA standards, EN60950 (IEC 950), and VDE 0160.
Model Number Structure
Model Number Legend
S8TS-@@@@@@-@@
1 1. Capacity 060: 60 W 030: 30 W 025: 25 W 2 3 4 2. Output Voltage 24: 24 V 12: 12 V 05: 5 V 3. Structure None: Screw terminals F: Connector terminals 4. Bus Line Connectors None: Basic Block only E1: S8T-BUS01 and S8T-BUS02 included
Ordering Information
Basic Block
Output voltage Output current Screw terminal type With Bus Line Connectors (See note 1.) 24 V 12 V 5V 2.5 A 2.5 A 5A S8TS-06024-E1 S8TS-03012-E1 --Without Bus Line Connectors (See note 2.) S8TS-06024 S8TS-03012 S8TS-02505 Connector terminal type (See note 3.) With Bus Line Connectors (See note 1.) S8TS-06024F-E1 S8TS-03012F-E1 --Without Bus Line Connectors (See note 2.) S8TS-06024F S8TS-03012F S8TS-02505F
Bus Line Connector
Type AC line + DC line bus (For parallel operation) AC line bus (For series operation or isolated operation) Number of Connectors 1 Connector 10 Connectors (See note 4.) 1 Connector 10 Connectors (See note 5.) S8T-BUS01 S8T-BUS11 S8T-BUS02 S8T-BUS12 Model number
Note 1. One S8T-BUS01 Connector and one S8T-BUS02 Connector are included as accessories. 2. Bus Line Connectors are ordered separately if necessary. 3. Attached connectors: 2ESDPLM-05P (for output terminal) and 3ESDPLM-03P (for input terminal) made by DINKLE ENTERPRISE. 4. One package contains 10 S8T-BUS01 Connectors. 5. One package contains 10 S8T-BUS02 Connectors.
Switch Mode Power Supply
S8TS
B-53
Specifications
Ratings/Characteristics
24/12-V Models (Basic Block: S8TS-06024@/S8TS-03012@)
Item Efficiency Input Voltage Frequency Current 100 V input 200 V input Power factor Leakage current Inrush current (25C, cold start) (See note 4.) Output (See note 3.) 100 V input 240 V input 100 V input 200 V input Single operation 100 to 240 VAC (85 to 264 VAC) 50/60 Hz (47 to 63 Hz) 24-V models: 1.0 A max. 12-V models: 0.7 A max. 24-V models: 0.5 A max. 12-V models: 0.4 A max. 0.35 mA max. 0.7 mA max. 25 A max. 50 A max. 24-V models: 22 to 28 V 12-V models: 12 V 10% (with V.ADJ) (See note 1.) 2% (p-p) max. 0.5% max. (with 85 to 264 VAC input, 100% load) 2% max. (with rated input, 10% to 100% load) 0.05%/C max. (with rated input and output) 1,000 ms max. 20 ms min. (with 100/200 VAC, rated input) 105% to 125% of rated load current, inverted L drop type, automatic reset Yes Yes, 4 Blocks max. Yes, 5 Blocks max. Yes Yes (color: red) Yes (open collector output), 30 VDC max., 50 mA max. Operating: Storage: Operating: Refer to the derating curve in Engineering Data. -25 to 65C (with no icing or condensation) 25% to 85%; Storage: 25% to 90% 100% to 125% of rated load current inverted L drop type, automatic reset 3% max. (with rated input, 10% to 100% load) 24-V models: 1.0 A x (No. of Blocks) max. 12-V models: 0.7 A x (No. of Blocks) max. 24-V models: 0.5 A x (No. of Blocks) max. 12-V models: 0.4 A x (No. of Blocks) max. 0.35 mA x (No. of Blocks) max. 0.7 mA x (No. of Blocks) max. 25 A x (No. of Blocks) max. 50 A x (No. of Blocks) max. Parallel operation 24-V models: 75% min.; 12-V models: 70% min. (with rated input, 100% load)
24-V models: 0.9 min.; 12-V models: 0.8 min. (with rated input, 100% load) (See note 3.)
Voltage adjustment range Ripple Input variation influence Load variation influence Temperature variation influence Startup time (See note 4.) Hold time (See note 4.)
Additional functions
Overcurrent protection (See note 4.) Overvoltage protection (See note 4.) Parallel operation N+1 redundant system Series operation Undervoltage indicator (See note 4.) Undervoltage detection output (See note 4.)
Other
Ambient operating temperature (See note 4.) Ambient humidity Dielectric strength
3.0 kVAC, 50/60 Hz for 1 minute (between all inputs and all outputs; detection current: 20 mA) 2.0 kVAC, 50/60 Hz for 1 minute (between all inputs and GR terminal; detection current: 20 mA) 1.0 kVAC for 1 minute (between all outputs and GR terminal; detection current: 20 mA)
Insulation resistance Vibration resistance Shock resistance Output indicator Electromagnetic interference EMI Power factor correction EMS Approved standards
100 M min. (between all outputs and all inputs, and between all outputs and GR terminal) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 150 m/s2, 3 times each in X, Y, and Z directions Yes (color: green) Conforms to FCC Class A, EN50081-1 Conforms to EN50081-1/1992 Conforms to EN61000-3-2, EN61000-3-2 A14 Conforms to EN61000-6-2/1999 UL: 508 (Listing; Class 2: Per UL1310), 1950, 1604 (Class I, Division 2, Groups A, B, C, D Hazardous Locations)) CSA C22.2 No.14, No.213 (Class I, Division 2, Groups A, B, C, D Hazardous Locations), No. 950 (Class 2) (See note 2.) EN/VDE: EN50178 (=VDE0160), 60950 (=VDE0806) cUL: 450 g max. 450 g x (No. of Blocks) max.
Weight
Note 1. Refer to page B-59 for details on adjusting the output voltage for parallel operation. If set to less than -10%, the undervoltage detection function may operate. Ensure that the output capacity and output current after adjustment do not exceed the rated output capacity and rated output current respectively. 2. Class 2 approval does not apply to parallel operation. 3. The output current is specified at power output terminals. 4. Refer to the explanations of functions on page B-56 for details. 5. Be sure to mount End Plates (PFP-M) on both ends of the Power Supply.
B-54
Switch Mode Power Supply S8TS
5-V Models (Basic Block: S8TS-02505@)
Item Efficiency (typical) Input Voltage Frequency Current Power factor Leakage current Inrush current (25C, cold start) (See note 2.) Output (See note 2.) Voltage adjustment range Ripple Input variation influence Temperature variation influence Load variation influence Startup time (See note 3.) Hold time (See note 3.) Additional functions Overcurrent protection (See note 3.) Overvoltage protection (See note 3.) Parallel operation N+1 redundant system Series operation Undervoltage indicator (See note 3.) Undervoltage detection output (See note 3.) Other Ambient operating temperature (See note 3.) Ambient humidity Dielectric strength 100 V input 240 V input 100 V input 200 V input 100 V input 200 V input 62% min. (with rated input, 100% load) 100 to 240 VAC (85 to 264 VAC) 50/60 Hz (47 to 63 Hz) 0.7 A max. 0.4 A max. 0.8 min. (with rated input, 100% load) 0.35 mA max. 0.7 mA max. 25 A max. 50 A max. 5 V 10% (with V. ADJ) (See note 1.) 2% (p-p) max. 0.5% max. (with 85 to 264 VAC input, 100% load) 0.05%/C max. (with rated input and output) 1.5% max. (with rated input, 10% to 100% load) 1,000 ms max. 20 ms min. (with 100/200 VAC, rated input) 105% to 125% of rated load current, inverted L drop type, automatic reset Yes No No Yes (with the external diode) Yes (color: red) Yes (open collector output), 30 VDC max., 50 mA max. Operating: Storage: Operating: Refer to the derating curve in Engineering Data. -25 to 65C (with no icing or condensation) 25% to 85%, Storage: 25% to 90% Single operation
3.0 kVAC, 50/60 Hz for 1 minute (between all inputs and all outputs; detection current: 20 mA) 2.0 kVAC, 50/60 Hz for 1 minute (between all inputs and GR terminal; detection current: 20 mA) 1.0 kVAC for 1 minute (between all outputs and GR terminal; detection current: 20 mA)
Insulation resistance Vibration resistance Shock resistance Output indicator Electromagnetic interference EMI Power factor correction EMS Approved standards
100 M min. (between all outputs and all inputs, and between all outputs and GR terminal) at 500 VDC 10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions 150 m/s2, 3 times each in X, Y, and Z directions Yes (color: green) Conforms to FCC Class A, EN50081-1 Conforms to EN50081-1/1992 Conforms to EN61000-3-2, EN61000-3-2A14 Conforms to EN61000-6-2/1999 UL: cUL: EN/VDE: 508 (Listing), 1950, 1604 (Class I, Division 2, Groups A, B, C, D Hazardous Locations) CSA C22.2 No.14, No.213 (Class I, Division 2, Groups A, B, C, D Hazardous Locations), No. 950 EN50178 (=VDE0160), 60950 (=VDE0806)
Weight
450 g max.
Note 1. If set to less than -10%, the undervoltage detection function may operate. Ensure that the output capacity and output current after adjustment do not exceed the rated output capacity and rated output current respectively. 2. The output current is specified at power output terminals. 3. Refer to the explanations of functions on page B-56 for details. 4. Be sure to mount End Plates (PFP-M) on both ends of the Power Supply.
Reference Value
Item Reliability (MTBF) Value 250,000 hrs min. Definition MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent the life of the product. The life expectancy indicates average operating hours under the ambient temperature of 40C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor.
Life expectancy
10 yrs min.
Switch Mode Power Supply
S8TS
B-55
Power supplies


▲Up To Search▲   

 
Price & Availability of S8TS03024

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X